Find the Parker Condition Monitoring resources you need to help with your project, including literature, blogs, videos, and more.
Protect your assets, improve productivity and increase uptime with your complimentary Gold Guide, a definitive reference guide to fuel, hydraulic, and lubricating oil for the marine industry including Sulphur Cap legislation.
All engine OEMs require under-piston used drain oil to be sampled from the engine; this is from the scavenge bottom drain. The oil is used for cylinder condition evaluation. Drain oil analysis is also a strong tool for judging the engine wear condition.
Monitor the health of lubricants and greases by taking a sample and analysing in one of the following products:
Lube oil water contamination: DIGI+
Lube oil base number and/or water contamination: DIGI+
Lube oil viscosity: Heated Viscometer
Lube oli multi-parameter analysis: Oil Test Centre
Monitor machinery wear by detecting wear debris in lubricants and greases by taking a sample and analysing it:
Magnetic iron wear debris in oil or grease: Ferrous Wear Meter (FWM+)
Continuously monitor the ferromagnetic iron (Fe) content in cylinder drain oil (CDO).
Coming soon! Learn more here:
Fully automated, continuous liner wear monitoring: Online Ferrous Wear Meter (OFWM)
Maintaining your machinery's oil is crucial, as it's the key lubricant preventing metal-on-metal contact in engines, hoists, and compressors, ensuring smooth operation.
Prioritising oil analysis is essential for maintenance teams to keep machinery running efficiently and reduce downtime, thereby optimizing output and cutting costs. Utilising advanced oil analysis tools, along with wear debris analysis and other condition monitoring techniques, is vital for the health and efficiency of heavy machinery.
Monitor the health of lubricants and greases by taking a sample and analysing in one of the following products:
Lube oil water contamination: DIGI+
Lube oil base number and/or water contamination: DIGI+
Lube oil viscosity: Heated Viscometer
Lube oli multi-parameter analysis: Oil Test Centre
Monitor machinery wear by detecting wear debris in lubricants and greases by taking a sample and analysing it:
Magnetic iron wear debris in oil or grease: Ferrous Wear Meter (FWM+)
Monitor the health of lubricants with sensors direct in the in-service fluid. Constant feedback to displays or integrated into supervisory panels and monitoring systems.
Lube oil contamination: Fluid Condition Sensor (FCS)
Lube oil condition: Fluid Property Sensor (FPS)
Monitor machinery wear by detecting debris in lubricants with sensors direct in the in-service fluid. Constant feedback to displays or integrated into supervisory panels and monitoring systems.
Machinery wear debris detection in fluids: Metallic Wear Debris Sensor (MWDS)
Monitor fluid particulate contamination in lubricants and hydraulics with sensors sampling directly the in-service fluid. Constant feedback to displays or integrated into supervisory panels and monitoring systems.
Fluid and particulate monitoring (Cleanliness Codes): iCount Particle Detector Range (iCountPD)
Lubricant condition and health play a vital role in keeping machinery operational. All machinery will wear with use, from bearings in electric motors to gearboxes. Parker condition monitoring offers a product range to monitor the lubricant and machinery health.
Monitor the health of lubricants and greases by taking a sample and analysing in one of the following products:
Lube oil water contamination: DIGI+
Lube oil base number and/or water contamination: DIGI+
Lube oil viscosity: Heated Viscometer
Lube oli multi-parameter analysis: Oil Test Centre
Monitor machinery wear by detecting wear debris in lubricants and greases by taking a sample and analysing it:
Magnetic iron wear debris in oil or grease: Ferrous Wear Meter (FWM+)
Monitor the health of lubricants with sensors direct in the in-service fluid. Constant feedback to displays or integrated into supervisory panels and monitoring systems.
Lube oil contamination: Fluid Condition Sensor (FCS)
Lube oil condition: Fluid Property Sensor (FPS)
Monitor machinery wear by detecting debris in lubricants with sensors direct in the in-service fluid. Constant feedback to displays or integrated into supervisory panels and monitoring systems.
Machinery wear debris detection in fluids: Metallic Wear Debris Sensor (MWDS)
Monitor fluid particulate contamination in lubricants and hydraulics with sensors sampling directly the in-service fluid. Constant feedback to displays or integrated into supervisory panels and monitoring systems.
Fluid and particulate monitoring (Cleanliness Codes): iCount Particle Detector Range (iCountPD)
Marine fuel deliveries are measured by volume but paid for by mass. Ensuring the fuel quality at the time of deliver and calculating the density is an integral part of good bunkering practices. Challenges with future fuels, including bio-content and stability issues, require even more of Parker's condition monitoring solutions to help companies measure compability, density and water content to calculate the mass of the fuel delivered.
Our onboard fuel labs can help ensure fuel is within the required specification under ISO 8217, Viscosity, Density, Water, CCAI, Compabibility, Pour Point, Salt. They can also help maintain bunker fuel samples for Port State Inspection under MARPOL 73/78 Annex VI.
Taking a representative sample is essential. Use proven samplers, sample capture and storage.
Fuel oil bunker drip samplers: Bunker Samplers
Capture samples in cubitainers and store in bottles: Cubitainer and Bottles
Securely store samples in a purpose made cabinet: Bunker Storage Cabinet
Monitor fuel by taking a sample and analysing in one of the following products:
Fuel oil vicosity: Heated Viscometer
Fuel oil density: Density Meter
Fuel oil compatibility, miscibility and stability: Compatibility Oven
Monitor fuel particulate contamination with sensors sampling directly. Constant feedback to displays or integrated into supervisory panels and monitoring systems.
Distillate fuel particulate monitoring (Cleanliness Codes): iCount Particle Detector range (fuel)
View our comprehensive product selection matrix to discover the right condition monitoring solution for your application.
Parker High Performance Flange System - HPF
Non-welding flange technology for high performance
F37 Flanges vs Welded Connections
Learn how Parker non welded connections can minimise set up time and maximise safety and cleanliness in this video.
Simpler, Safer Flanges
Learn about this time-saving and cost saving alternative to welding
Parker Onsite Container for More Flexibility and Cost Savings
Discover how Parker used CFD to establish an optimised hydraulic tank design when challenged with improving deaeration while reducing tank size.
The Parker Service Master COMPACT
Learn about our measurement device for hydraulic service applications.
Ideal for service applications
Need Help?
In today’s demanding markets a proactive approach to maintenance is essential. Extreme conditions, inspection difficulties, and workforce safety make condition monitoring crusial. Implementing comprehensive oil condition monitoring solutions, including online sensors and on-site testing technologies, ensures you effectively protect your assets and profits.
Parker has extensive experience in serving marine, offshore, and industrial sectors with advanced condition-based monitoring solutions. Our offerings include state-of-the-art machine oil condition monitoring for in-service lubricants, greases, bunker fuels, exhaust emissions, wear metals, and acoustic emissions. We also provide robust sampling systems and global logistics for large-scale used oil analysis and other secure sampling needs.
We are dedicated to delivering the perfect combination of technology, expertise, and information. This enables you to manage risk, cut operational and maintenance costs, and enhance uptime, reliability, efficiency, and profitability through effective oil condition monitoring.